Ax-Series - Alert ID 166 - Drop Generator Temperature Over the Maximum Limit

Problem description

Ax-Series Range.png

CAUSE

REMEDY

The printer is operating in a temperature environment that is outside of the specified range.

Check the temperature of the environment. The operating temperature should be between +5ºC to +45ºC (42ºF to 112ºF). Move the printer to an environment that is within specification, or adjust the temperature of the environment.

The drop generator has overheated.

Shut down the printer and allow the drop generator to cool down:

The drop generator is faulty.

Shut down the printer and contact your local support office: