Ax-Series - How to Reduce the Digital Gearbox Multiplier
Description
NOTE
|
- Use the lowest possible Digital gearbox multiplier value to achieve a good Encoder stroke resolution value.
- The save button will not be available for selection if the Encoder stroke resolution (pulses/strokes) value is too high. The range is 1-100.
|
Step 1
Reduce the Digital Gearbox Multiplier
To reduce the digital gearbox multiplier:
- On the TouchScreen, select Home > Setup > Production Line Setup > Line Movement > Set Calibrations Settings.
- Adjust the Digital gearbox multiplier and Digital gearbox divider settings to set the Encoder stroke resolution (pulses/stroke) to the correct value for the print application.
Print Application |
Encoder Stroke Resolution Value |
| High-speed printing. |
10, or close to 10. |
| Medium- and low-speed printing. |
Between 10 and 20. |
- Select Save.
[End of Procedure]