Ax-Series - How to Edit a Counter Element

Step 1

To Edit a Counter Element

  1. On the TouchScreen, select Home > Edit current label.

  2. Select the counter element.

  3. Select the Edit icon.

    edit.jpg

  4. Select Edit Variable at the top of the screen.

  5. Select the Edit icon.

    edit_2.jpg

  6. These counter settings can be defined:

    Setting Name

    Explanation

    Name Enter the name of the counter element.
    Format

    Input the required counter format:

    0 - Mandatory numeric character (0-9)

    L - Mandatory alpha character (A-Z or a-z)

    Start value Input the counter start value.
    Repeat count Enter the number of times the same counter value will be repeated.
    Show additional properties Tick the Show additional properties tick box to show more counter settings.
    Step

    Enter the number of steps and the direction that the counter will count it, for example:

     

    If the Start value is set to 00 and Step is set to 5, the counter will count upwards from 00 in the following sequence: 00, 05, 10, 15, etc. The counter will reset when it reaches the Upper limit value.

     

    If the Start value is set to 20 and Step is set to -5, the counter will count downwards from 20 in steps of 5 in the following sequence: 20, 15, 10, 05, etc. The counter will reset when it reaches the Lower limit value.

    Lower limit Enter the minimum counter value. When the counter reaches this value it will reset.
    Upper limit Enter the maximum counter value. When the counter reaches this value it will reset.
    Leading zeros Tick the Leading zeros tick box to add padding characters to the counter.
    Padding character If the Leading zeros tick box has been ticked, this setting is used to define the padding character that will be printed.
    Trigger

    Specify what method will trigger the counter value to update:

     

    Product Detect - The counter will be triggered each time a product detect signal is received.

     

    Another Counter - The counter will update when another selected counter element reaches its Upper limit or Lower limit value.

    Language

    Select the language:

    • Western
    • Arabic
    • Farsi
    Store persistent counter value

    Select when the counter value is saved:

    • never
    • on print start
    • on print complete

     

  7. Select the green Tick icon to confirm the counter settings.

  8. Select the green Tick icon to add the counter element to the label design.

  9. Select the Save icon to save the change.